Configurable wide bandwidth wireless digital acquisition system. 256 channel recording wirelessly up to 10 meters or onto MicroSD card.

Very flat frequency response to accurately record both low-frequency Alpha and Theta oscillations, and high-frequency Single Unit Action Potentials.

FreeLynx utilizes a separate, customizable Analog Front End (AFE) interface that easily adapts to multiple FreeLynx standard configurations. This enables the user to optimize weight distribution, record from multiple implant sites, adapt to varying channel counts, or incorporate animal physiology sensors. With this technology, Neuralynx is able to rapidly develop custom AFEs – in 32 channel increments - to meet specified multi-site implant requirements.

Comprehensive line of accessories, including omni-directional video tracking LEDs and securely mounted self-aligning QuickClip® EIBs.

Advancements in Wireless Technology for Single Unit Electrophysiology Recording


  • FreeLynx as a Stand-alone Acquisition System:
    Use Cheetah to directly control a FreeLynx without a Digital Lynx SX, acquiring up to 256 channels per Cheetah / FreeLynx system.

    • Switch between two recording modes at any time:
      • wirelessly transmit data to Cheetah acquisition computer
      • record data to onboard microSD card for later retrieval

  • Combine with Digital Lynx SX:
    One or two FreeLynx (up to 128 channels each) can be used simultaneously with the Digital Lynx SX…

    • Switch between two recording modes at any time:
      • wirelessly transmit up to 128 channels from each FreeLynx OR
      • record up to 256 channels to onboard microSD card for later retrieval

    • Simultaneously record from any Digital Lynx SX input: FreeLynx, Combo Board, Input Board and HS-Mux series headstages
    • Real-time, closed-loop signal processing with HPP
  • Features:

    • 9-axis motion tracking (gyro, accelerometer, compass)
    • Rechargeable battery options up to 24+ hour recording
    • Backpack option to reduce weight on subject’s head and neck
Included:
  • WiFi Access Point connects to Cheetah workstation or Digital Lynx SX/SX-M for wireless acquisition
  • IR Transmitter & Receiver for remotely powering FreeLynx on/off
  • Power tether for continuous recording without battery
  • Power Stick for powering FreeLynx on/off while Protective Cover is installed
  • USB Charging Hub for recharging FreeLynx batteries
Sold Separately:
  • Simulation Training Weights
    Simulates mass and balance of FreeLynx to prepare subjects.
  • Custom Protective Covers
    Prevents NHP subjects from damaging FreeLynx.
  • 3.3V Video Tracking LEDs
    Omni-directional video tracking LEDs.
  • QuickClip EIBs
    Securely mounted self-aligning QuickClip® EIBs.
  • High Capacity Micro SD Card
    Install on each FreeLynx to record data locally to the SD Card.

Specifications

Dimensions 30 x 30 x 30 mm
Base Mass 11.5 grams
Transmission Range up to 10 meters, depending on environment
Resolution 16 bit
Sample Rates up to 30 kHz per channel
Frequency Range 0.1 Hz - 8 kHz from each electrode
Input Range +/-5 mV
Noise < 2.5 μV RMS (input referred)
Power Source quick-change battery or power tether with no hassle swap
Battery Run Time 30 minutes to 24+ hours, depending on battery

FreeLynx Analog Front End (AFE) Configuration Options:

FreeLynx AFE Configuration Options

Wireless Setups Mass Comparisons:

FreeLynx Wireless Setups Mass Comparisons

“Our lab has experimented with a number of wireless data acquisition systems for both rodent and primate electrophysiology. We are very pleased with the recording quality and overall performance of Neuralynx’s [FreeLynx] - which we find to be virtually indistinguishable from traditional wired systems. We would happily recommend this device for any researcher seeking a reliable and user friendly system for performing wireless electrophysiology recording.”

Carol A. Barnes, Ph.D. Director, ARL Division of Neural Systems, Memory and Aging, University of Arizona