MISSION CRITICAL—The bedside is no place for chance
or adventure in neural recording.
- Lowest noise at 1.3 μV rms
- Extremely high common mode rejection.
- Connect to the electrodes and get signal not noise.
- Buffered leads with active shields, fiber optic links.
- Unparalleled flexibility in signal filtering and reference selection.
- Designed Reliability
- Serviced Reliability – Mission Critical Service Plans, Instant ATLAS Loaner
Neuralynx Understands
Mission Critical
Space Flight Certified 160 channel system
STS-90 Neurolab 1998
PERFORMANCE—Record neural activity with the highest fidelity.
- Highest Definition recording at 24 bit resolution.
- Highest Density of electrodes.
- Widest Dynamic Input Range prevents signal clipping. Directly samples all signal types from Stimulus, EMG, EEG, to small Extracellular Single Action Potentials.
- Records DC potential shifts.
- Highest clinical sampling rate at 40 kHz.
SAFETY—The patient comes first.
- Designed to Recognized Standards (EN, IEC, UL).
- Cleared for human use in USA and EU (FDA, MDD, CE).
- Manufactured under ISO 13485 Certification.
- Crafted in USA with twenty years of experience in research systems.
EASE OF USE—Eliminate bottlenecks in the data workflow.
- Easy patient connection.
- Easy acquisition monitoring.
- Easy experimental control and data analysis.
- Easy Training, on site or in Bozeman, MT.
| Last Generation | Next Generation - The ATLAS Neurophysiology System | ||
| Channels | 128 | 512 | 4 times more channels! |
| Analog to Digital | 16 bits | 24 bits | 8 more bits |
| Precision/Accuracy | 14 bit linear | 19 bits linear | 32 times more range/resolution |
| AC Input Range | -8.1 mV to 8.1 mV | -132 mV to 132 mV | 16 times more input range - "throw away the gain knob" |
| DC Input Range | N/A | -1V to 1V | Record DC shifts |
| Common mode rejection | 90 dB | 110 dB | How well the amplifier extracts signal from noise |
| Sample Rate | 32 kHz | 40 kHz | Highest sampling rate |
| Noise | 3 μV rms | 1.3 μV rms | Half the noise |
| System Configuration | Stand-alone | Stand-alone Parallel operation with clinical EEG Networked operation with NetCom nodes |
Neuralynx ATLAS gets you to PUBLICATION FASTER! |
* Stead et al., (2010) Microseizures and the spatiotemporal scales of human partial epilepsy.
Brain 133: 2789-97.
Quiroga et al., (2005) Invariant visual representation by single neurons in the human brain. Nature 435:1102-1107.
Quiroga et al., (2005) Invariant visual representation by single neurons in the human brain. Nature 435:1102-1107.